Princeton University
Hydraulic Elevator
Date: June 1, 2009
Section 14212 – Page 1
SECTION 14212
HYDRAULIC ELEVATOR
PART 1 GENERAL
1.1 DESCRIPTION
A. Work of this section includes all labor, materials, equipment and service necessary to
complete the elevator or elevators as shown on the drawings and specified herein and/or
specified in the master installation and maintenance specifications.
B. All work will be installed in accordance with the most restrictive requirements of the
ASME A17.1 Code (currently 2004 with 2005 supplements) as specified in the 2006
International Building Code, New Jersey Edition. Specification writer shall see section
1.4 of the Princeton University Design Standards. Since these codes do change
periodically, see the University Code Analyst cited in section 1.4 before citing a
specific regulatory code.
1.2 RELATED SECTIONS
NOTE TO SPECIFICATION WRITER: Insure that the items listed below are
appropriately addressed in other specification sections.
A. Protecting hoistway during installation of equipment. Barricades installed by the General
Contractor will be maintained by the Elevator Contractor.
B. Cutting and patching.
C. Grouting under hoistway doorsills and at jambs.
D. Concrete shaft and slabs.
E. Machine room enclosure.
F. Access ladder.
G. Pit waterproofing and sump pump installation.
H. Ventilation and Heating of hoistway and machine room.
I. Life safety system speakers
J. [Floor tile] [carpet] [Delete if elevator contractor is required to install the floor tile or
carpet in the elevator cab.]
K. Electrical Requirements: [NOTE to specification writer: Delete any items not
required by this project. Those items that will be the responsibility of the elevator
Commenti su questo manuale